Application analysis of current sensor in DC charging pile


(1) The charging pile, no matter how high the power, is composed of N AC-DC power modules in parallel,

Module specifications:

Power: 10kW --- 35kw, input voltage: 380VAC, three-phase,

Output voltage: 200V --- 600V, output current: 50A --- 200A,

(2) Position 1, three-phase PFC sensor, applicable to Senko one-way sc820, unit dosage: 2 pieces;

Position 2, AC to DC, DC output current sensor, Senko unidirectional sc820, sc780 applicable unit dosage: 1 piece;

Position 3, DC to DC level, DC input current sensor, Senko unidirectional sc820, sc780 applicable, unit dosage: 1 piece;

Position 4, DC to DC level, DC output current sensor, Senko unidirectional sc820, sc780 applicable, unit dosage: 1 piece;

(3) Total:

Each AC-DC power module, unit consumption: 5, Senko applicable model: sc820; sc780, sc780 consumption is the majority;

At the same time, it should be noted that the manufacturer of charging point is not our direct customer, but the manufacturer of module.

Module manufacturers often manufacture communication power supply and charging module.